This uninstallation manual applies to all Spaceti office sensors with part numbers starting with SCP, SRP, and SC2.
Tools:
TL1 | undeploy tool | undep002 |
TL2 | Isopropyl alcohol (IPA) |
|
TL3 | Cleaning tissues or lint-free cloth |
|
Img 1 - Undeploy tool
Unistallation process
Standard Removal (Sensor Only):
Insert the tool TL1 into the undeploy hole
Img 2 - Undeploy tool usage
Press the tool TL1 into the undeploy hole and apply pressure against the spring inside the sensor. Feel the resistance of the spring and continue pressing until it reaches the end.
Rotate the sensor counterclockwise.
Img 3 - push and rotate
Unbuckle the sensor from the platform while keeping the platform attached to the chosen spot.
Fully Removal (sensor + platform + sticker):
If the sensor needs to be removed together with the platform (e.g. for installation in a different location) and the adhesive sticker, follow these steps:
Note: Do not use the undeploy tool TL1 in the first step.
Slowly rotate the sensor clockwise to gradually release the adhesive from the surface (e.g. table, glass, or wall).
Once the adhesive bond is weakened, gently remove the sensor along with the platform.
Clean the surface using isopropyl alcohol (IPA) and cleaning tissues or a lint-free cloth to remove any adhesive residue.
Use the undeploy tool TL1 to detach the platform from the sensor, following the same steps as in the standard removal process.
Note: Always replace the used installation platform with a new one that has fresh adhesive to prevent the sensor from falling.
Img 4 - rotate to unstick (clockwise direction)